There are two antenna series:
● Standard Version: with 50 ohm high voltage connector and impedance adapter for antenna
● Special version: the pulse generator is placed below the ground plane.
Connected to a 30 kV, 115 ps pulse generator, the antenna can theoretically produce more than 8.3 kV/m at a distance of 20 m. The antenna can be oriented in every direction. In a receive mode, its output voltage is proportional to the incident E-field.
Applications:
● Immunity test of electronic equipment
● Buried object recognition
● Broadband jammer
● Broadband source for vulnerability research through transfer function measurement
● Industrial applications (for example, detection of underground leakage or defective pipelines)
● Avalanche rescue operations, etc
Specification:
Type | HIRA180 / HIRA180S |
Reflector diameter | 180 cm |
Reflector type | half paraboloidal |
Frequency range | about 100 MHz – 6 GHz |
Rise time | about 100 ps |
Gain | frequency dependant |
Polarisation | vertical |
rE value (for a 130 ps / 20 kV pulser)1 | 98 kV |
rE value (for a 130 ps / 30 kV pulser)1 | 147 kV |
rE value (for a 1 ns / 20 kV pulser)1 | 12.7 kV |
Theoretical far field limit (for a 130 ps / 20 kVpulser)2 | 42 m @ 130 ps |
Theoretical far field limit (for a 1 ns / 20 kV pulser)2 | 5.4 m @ 1 ns |
Maximum peak voltage (for pulses shorter than 1 ns) | 20 kV (HIRA180) 75 kV (HIRA180S) |
Power capability (continuous) | 160 W |
Maximum energy | 26 kJ |
S11 | better than 9.5 dB, up to 2.5 GHz |
Input impedance | 50 Ω |
Connector | HIRA 180: HN (f) HIRA 180S: HVM50K (f), montena proprietary |
Dimensions of the ground plane | 190 x 190 cm |
Overall dimensions L x W x H | 190 x 190 x 220 cm |
Weight | 90 kg |